Contactor Coil : AC240V
Model : LS MEC GMC-9
TOR : GTH22/3 4-6A
Timer : Anly AH3-1 240V 3Sec Timer
Contactor will turn on & off in between in duration of 3 second each... Non stop...
Method & Theory :
NC of the contactor control the current into the 1st Timer..
1st Timer control the current from live wire to the contactor coil..
NO of the contactor control the current into the coil from the 2nd Timer & also provide live current into the 2nd Timer..
2nd Timer control the current from live wire to the coil...
Each rely on each others to fully operate..
7 comments:
is it possible to connect a single timer,so that the starter gets off after a specified time.
Can you include push button on this diagram..
Could you provide the diagram?
could you prowid diagram
skaruri, is possible.. but u need twin timer for that..
aie, where do you want the push button to be..??
Hue Nest & Sahabat, no problem, I will upload it on my next post..